PEM & Alkaline
Water Electrolyzer
PEM & Alkaline Common Specification
Mass Flow Control: Turndown 100:1, Auto N2 Purge
Electrolyte Circulation (PEM):
– DI Water Temperature Control(RT ~ 95°C), DI Water Level Control & Alarm, Auto Fill
– Water Conductivity Monitoring, DI Water & Gas Seperation
– DI Water Flow Control, Water Filtering(Micro & ion)
Electrolyte Circulation (ALK, AEM):
– Liquid Temperature Control(RT ~ 95°C), Liquid Level Control & Alarm, Auto Fill(Option)
– Liquid & Gas Seperation
– Liquid Flow Control
Gas Colling: Gas cooling and Trap (Condensation water and gas split)
Concentration Sensor: H2 in O2, O2 in H2 (0-5%, 10% Vol)
Back Pressure Control: Max 10bar (30Bar – option)
Cell voltage monitoring: Nominated Channel, ±5V/Ch
Options
– Integrated AC impedance measurement system (10mHz ~ 10kHz)
*All systems include automation control and monitoring software.
Single Cell Test Station
- SE300-PEAL, SE500-PEAL
- Up to 500W
- 600(W) X 1100(D) X 2000(H) mm
Stack Test Station (1KW - 3KW)
- SE1K-PEAL, SE3K-PEAL
- Up to 3kW
- 800(W) X 1300(D) X 2000(H) mm
Stack Test Station (5KW - 10KW)
- SE30K-PEAL, SE50K-PEAL
- Up to 10kW
- 1400(W) X 2200(D) X 2000(H) mm
Stack Test Station (30KW - 50KW)
- SE30K-PEAL, SE50K-PEAL
- Up to 50kW
- SE30K-PEAL, SE50K-PEAL
Stack Test Station (100KW)
- SE100K-PEAL
- Up to 100kW
- 1500(W) X 3000(D) X 2200(H) mm
Stack Test Station (200KW)
- SE200K-PEAL
- Up to 200kW
- 1800(W) X 4000(D) X 2200(H) mm